Construction characteristics
Coax. 75 Ω coax (1 each)
Conductor: 2.00 mm² bare copper conductor insulated with PE
(2 each)
Shielded twisted pair: 0.50 mm² bare copper conductor insulated with PE. 2 conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil (1 each)
Shielded twisted quad. 0.22 mm² bare copper conductor insulated with PE. 4 conductors twisted
together with a tinned copper drain wire and aluminium/polyester foil (1 each)
Twisted pair: 1.34 mm² bare copper conductor insulated with PE
2 conductors twisted together (2 each)
Filling compound: The cable is filled with cable filling compound
Shield: Aluminium/polyester foil and tinned copper drain wire, coverage 100%
Outer jacket: Polyurethane jacket. Colour yellow
Mechanical characteristics
Diameter: 14.50 mm ±0.40 mm
Weight in air: 255 kg/km nom
Weight in seawater: 86 kg/km nom
Min. bending radius, static: 150 mm
Min. bending radius, dynamic: 215 mm
Depth rating: 5,000 m
Electrical characteristics
Operating voltage: 600 V for 0.50 mm², 2.00 mm² and 1.34 mm² conductor
24 V for 0.22 mm² conductor
Conductor resistance: ≤ 135 Ω/km for coax
≤ 10.0 Ω/km for 2.00 mm² conductor
≤ 41.0 Ω/km for 0.50 mm² conductor
≤ 96.2 Ω/km for 0.22 mm² conductor
≤ 15.3 Ω/km for 1.34 mm² conductor
Insulation resistance: ≥ 5,000 MΩ×km for coax, 2.00 mm² conductor and 1.34 mm² conductor
≥ 10,000 MΩ×km for 0.50 mm² conductor and 0.22 mm² conductor
Capacitance: 59 pF/m for coax
80 pF/m for 0.50 mm² and 1.34 mm² pair
65 pF/m for 0.22 mm² quad
Attenuation: 3.79 dB/100 m at 5 MHz for coax
5.32 dB/100 m at 10 MHz for coax
67.11 dB/100 m at 1,000 MHz for coax