Power/signal cable - Type 4622Power/signal cable - Type 4622

Construction characteristics

Power conductor: 1.00 mm² bare copper conductor insulated with PE
(2 each)
Shielded twisted pair: 0.22 mm² bare copper conductor insulated with PE.
2 conductors twisted together with a tinned copper drain wire,
aluminium/polyester foil and a PE sheath (1 each)
Shielded twisted pair: 0.22 mm² bare copper conductor insulated with PE. 2 conductors twisted
together with a tinned copper drain wire and an aluminium/polyester foil (5 each)
Shield: Tinned copper braid, coverage 85%
Outer jacket: Polyurethane jacket. Colour blue

 

Mechanical characteristics

Diameter: 12.00 mm ±0.40 mm
Weight in air: 200 kg/km nom
Weight in seawater: 110 kg/km nom
Min. bending radius, static: 80 mm
Min. bending radius, dynamic: 120 mm
Depth rating: 3,000 m

 

Electrical characteristics

Operating voltage: 600 V DC for 1.00 mm² conductor
24 V DC for 0.22 mm² conductor
Test voltage: 3,000 V DC for 1 min for 1.00 mm² conductor
1,500 V DC for 1 min for 0.22 mm² conductor
Conductor resistance: ≤ 20.0 Ω/km for 1.00 mm² conductor
≤ 96.2 Ω/km for 0.22 mm² conductor
Insulation resistance: ≥ 100 MΩ×km (cond. - cond.)
≥ 50 MΩ×km (cond. - shield)
≥ 10 MΩ×km (shield - shield)
Capacitance: 85 pF/m for 0.22 mm² pair
Impedance: 60 ±5 Ω at 1-10 MHz for 0.22 mm² pair
Attenuation: 10.0 dB/100 m at 1 MHz
25.0 dB/100 m at 10 MHz

כבלים באיכות הגבוהה ביותר המיועדים לענות על דרישות הלקוח עבור עבודה בסביבה תת-ימית.

יש ליצור קשר עם מנהל תחום ים בויסנס טכנולוגיות על מנת לתכנן ולבצע כל פרויקט בצורה הטובה ביותר.